Rated supply voltage |
100 – 277 V |
AC voltage range |
90 – 305 V |
DC voltage range |
176 – 288 V |
Rated current 12 V (at 120 V, 60 Hz, full load) |
0.59 A |
Rated current 12 V (at 230 V, 50 Hz, full load) |
0.32 A |
Rated current 12 V (at 277 V, 60 Hz, full load) |
0.26 A |
Rated current 24 V (at 120 V, 60 Hz, full load) |
0.58 A |
Rated current 24 V (at 230 V, 50 Hz, full load) |
0.32 A |
Rated current 24 V (at 277 V, 60 Hz, full load) |
0.26 A |
Mains frequency |
0 / 50 / 60 Hz |
Efficiency 12 V (at 120 V, 60 Hz, full load) |
> 87 % |
Efficiency 12 V (at 230 V, 50 Hz, full load) |
> 85 % |
Efficiency 12 V (at 277 V, 60 Hz, full load) |
> 87 % |
Efficiency 24 V (at 120 V, 60 Hz, full load) |
> 89 % |
Efficiency 24 V (at 230 V, 50 Hz, full load) |
> 85 % |
Efficiency 24 V (at 277 V, 60 Hz, full load) |
> 89 % |
λ 12 V (at 120 V, 60 Hz, full load) |
0.99 |
λ 12 V (at 230 V, 50 Hz, full load) |
0.95 |
λ 12 V (at 277 V, 60 Hz, full load) |
0.96 |
λ 24 V (at 120 V, 60 Hz, full load) |
0.99 |
λ 24 V (at 230 V, 50 Hz, full load) |
0.95 |
λ 24 V (at 277 V, 60 Hz, full load) |
0.96 |
Max. input power in no-load operation |
0.5 W |
Output voltage tolerance 12 V |
-0 / +10 % |
Output voltage tolerance 24 V |
-0 / +5 % |
Output power (ta ≤ 122 °F) |
60 W |
Output power (ta > 122 °F) |
42 W |
Output power range |
4.8 – 60 W |
Turn on time (output) |
≤ 0.5 s |
Turn off time (output) |
≤ 1 s |
Hold on time at power failure (output) |
10 ms |
Mains surge capability (between L - N) |
1 kV |
Mains surge capability (between L/N - PE) |
1 kV |
Surge voltage at output side (against PE) |
< 500 V |
Ambient temperature ta |
-13 ... +140 °F |
Ambient temperature ta (at life-time 50,000 h)
(1) |
-13 ... +113 °F |
Storage temperature ts |
-40 ... +185 °F |
Dimensions L x W x H |
9.84 x 1.57 x 0.83 inch |
Hole spacing D |
8.78 inch |